Office : Raja Survey
Nama : Ahmad Wahyudi
Tlp : 021 3649 5553
Fax : 021 7303447
Hp : 0812-1807 0051 (AS)
0878-7841 4326 (XL)
Email : yudi.rajasurvey@gmail.com
YM : rajasurvey27
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Alamat : JL Pesantren no.64
Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Rabu, 05 Februari 2014
Minggu, 12 Januari 2014
Jual ATTEN KPS-3030DA Adjustable Switching Power Supply
ATTEN KPS-3030DA Adjustable Switching Power Supply
KPS switching power supply series
Teaching electronic production line 5. Communications industry
applications. Development of technological products. Laboratories.
Product Type: KPS-3030DA
Product weight: 9kg
Product size: 337 × 263 × 173 ( L × W × H) mm
Outline
KPS-3030DA model power supply, adjustable for high efficiency switching
power supply. It has with a load capacity, high reliability and
efficiency, voltage and current continuously adjustable DC power supply,
small size, light weight. Over-temperature, over voltage, overload,
short circuit protection, suitable for the development of technological
products, laboratory, teaching, electronic production lines, as well as
the communications industry.
Technical parameters
a) Input voltage: AC 220V ± 10% 50Hz
b) continuously adjustable output voltage : 0-30V ( DC)
c) Output current : 0-30A ( DC) continuously adjustable current limit ( 0.2A or more can adjust)
d) Rated output power: 900W
e) Accuracy: 0.1 ± 2 words
f) full load efficiency: e 84%
g) Wen-bo noise Vpp: d 2%
h) voltage stability: d 0.5%
i) Load stability: d 0.1%
j) Protection: over-current, over-voltage, short circuit, over-temperature protection
k) the working cooling mode: air-cooled
l) Working temperature : 0-40 ° C
m) Rated working efficiency e 84%
n) Voltage stability: d 1% power stability d 0.5% Load stability d 1% ripple
Precautions
AC input: AC input is 220V ± 10% 50Hz ( 110V ± 10% 60Hz in the back of the chassis will be marked) .
1. cooling: cooling fan at around the mouth and machinery ventilation
should be sufficient space to facilitate cooling. This power machine
equipped with a temperature switch will automatically rotate when the
machine heating element temperature g 45 ° C fan cooling. Do not place
the ambient temperature exceeds 40 ° C.
Over-temperature protection: This power supply has over-temperature
protection When machine heating element temperature exceeds 65 ° C, the
output power off and wait for the power supply temperature cooling
recovery of output function.
Method of operation
a) Connect the power supply ( AC220V ± 10% ) .
b) Turn the power switch, the switch indicator is green.
Adjust the voltage knob to the desired output voltage.
1. Connect external load to the " + " " - " output terminal.
2. constant current regulation: in the boot state, the current
adjustment knob clockwise to the maximum, adjust the load current point
to the desired setting, and then adjust the current knob
counter-clockwise so that the voltage starts to fall under the ammeter
current is required to set a constant current.
3. If you encounter header CC ( red) lights, the power supply is limiting state ( Any flow should header CV ( green) lights) .
Note
1. Do not start with a load power switch, doing so can damage the power supply and the load.
2. This power supply is built-in thermistor to prevent instant boot
overshoot Do not / boot, otherwise easily damage the power off in rapid
succession.
Service
Replace the fuse
If the fuse blows, the power supply will stop working, encountered such
a situation must find out the cause of the blown fuse, and correct and
then replace the fuse with the same value, in addition there is a
problem generally fuse box do not open.
( 2) maintenance
The power internal burns must be repaired by a professional electrical
maintenance personnel, or send the dealer repair by the manufacturer and
shall not be repaired to ensure safety.
Warning: the KPS-3030DA switching power supply, internal high voltage
lines, the non-professional maintenance personnel shall not carry out
maintenance, to avoid danger.
Power installation, use and maintenance instructions
Maintenance of the installation, there are many special precautions for the following special instructions:
a) After opening the package, please check carefully match the
requirements of the Specification of the aircraft with the manual is
consistent with the carrying, at the same time whether the order
contract agreed. Event of any discrepancy, please contact our sales
department to discuss ways to properly handle.
As a first step before using, must be reliable grounding of the the
atten power metal housing to ensure safety, but not mistakenly housing
connected to the zero line.
1. before the installed power test run, check again and proofreading,
make sure that the inputs and outputs, AC and DC, positive and negative
voltage value and current value, no doubt correctly, put an end to then
reverse fault, high-voltage short circuit from occurring.
2. The power does not allow for long-term is in full working
condition, or they may be caused by man-made early failure. The order
should be based on actual operating current to an allowance.
3. In order to achieve adequate cooling effect, the atten power should
be installed in a location with good air convection conditions. General
requirements for the power work should be well ventilated. In addition,
the power supply housing are not allowed to place other items.
4. atten power applies mainly resistive load, if the need to apply
mainly to capacitive or inductive-based load should be explained in the
contract, due to an oversight of the nature of the load Lane wrong, it
should be timely with our sales department contact to seek appropriate
recovery plan.
5. For high voltage power supply, it is necessary to reiterate the
importance of safety. The use of the process and power outages are not
touch output port.
6. the atten power failure, in the most efficient way of delivering
the same defective product to the Company, the Company will consider the
situation, or to repair or replace. The user must not be allowed to
atten power forcibly demolished, or will give the Company on the cause
of the failure analysis to determine the cause difficulties and both
suffered the loss.
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek D705 Digital Multimeter
Protek D705 Digital Multimeter
Protek D705
a) Compact tru-rms meter for service technicians.
b) The Proteck D705 is the solution for a wide of electrical and electronic testing applications.
c) It has to set with combination of precision, ease-of-use, safety and reliability.
Features:
a) True RMS
b) 25 segments bar graph
c) Back-lit display ( White LED)
d) AC/ DC ยต A measurements
e) Capacitance measurements
f) Data hold and range Hold
g) Auto Power off function ( 30min)
h) Diode and Continuity Beeper tests
i) Frequency and Duty cycle measurements
j) MAX/ MIN/ AVG mode ( Sampling rate: 100ms)
k) 5000 count LCD display ( Black & White STN)
l) IEC 1010-2-032, CATIII 1000V Safety protection
m) K-Type thermocouple temperature measurements
n) Measures DC Voltage to 1000V, AC Voltage to 1000V and Resistance to 40M©
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 3290N Hand-Held 2.9 GHz RF Signal Strength Analyzer
Features
1. Frequency Range: 100KHz ~ 2.9GHz
2. WFM/ NFM/ AM/ SSB modulated signals may be measured
3. 125 Ch/ sec scan rate
4. High sensitivity ( -117dBm max)
5. Signal Levels up to 160Channels can be displayed simulaneously on the LCD
6. Sweep Trigger Mode: Free Run, Single Run, Continuous Wave, Squelch Run
7. Sweep Speed: 500 to 2000msec
8. LED Backlight LCD ( 192x192 dots)
9. PLL tuning system for precise frequency measurement and tuning
10. Built-in Frequency Counter
11. RS232C interface
12. Built-in speaker
13. Hand-Held and battery operated
Major differences between 3290N and 3290
1. Frequency resolution of 3290N was improved compared to 3290.
2. The 3290N provides you with more convenience because it has
additional functions such as Marker and Delta Marker that the 3290 does
not have.
3. The 3290N can be reached to Menu much faster through the changed shortcut key function instead of previous tree structure.
4. The accuracy of 3290N was enhanced through more segmented calibration
5. The 3290N provides the GUI program which is capable of bi-directional control for user.
6. The firmware can be upgraded easily via RS-232C.
7. The reference level can be adjusted.
8. The 3290N has a user-friendly icon display function.
9. The 3290N has more than 10 times of data memory compared with 3290.
Product Information
The Protek 3290N is a high quality hand-held style RF Field Strength
Analyzer with wide band reception ranging from 100kHz to 2900MHz. The
3290N is a compact and lightweight portable analyzer and is a must for
RF technicians. Ideal for testing, installing and maintenance of Mobile
Telecommunications Systems, Cellular Phones, Cordless Phones, CB Radio,
Paging Systems, Cable TV and Satellite TV Reception Systems, Hidden
Camera Detection and Teletapping Detection. Comes with Carrying Case,
Software, Manual, Ear Phone, Coax Cable, Holster, Batteries ( 6AA) ,
RS-232C Cable, Connector, Antenna and Carrying Strap.
Specifications
Frequency
a) Frequency Range : 100 KHz to 2.9 GHz
b) Resolution : 3.1255 kHz
c) Accuracy : TXO: ± 3ppm
d) Display : ± 1.5ppm
e) Modulation : W-FM: 180 kHz
f) N-FM : 12.5 kHz
g) AM/ SSB : 2.4 kHz
h) Step Range : AM/ SSB: 2.5 kHz Fixed
i) FM : Multiple of
j) Span Range : AM/ SSB: 400 kHz Fixed
k) FM : Multiple of 1 MHz
l) Frequency Selection : Start, Stop, Center Span Setup
Amplitude
a) Measurement Range : -20 dBm to -100 dBm
b) Average Noise Level : -100 dBm
c) Amplitude Units : dBm, dBmV, dBuV
d) Reference Level Accuracy : ± 2 dB
e) Reference Level Range : + 20 dBm to -70 dBm
f) Log Scale : 10dB/ DIV
g) Internal Atten : 10dB
Sweep
a) Speed : 500 to 2000 msec
b) Trigger Source : N-FM, W-FM, AM, SSB
c) Trigger Mode : Free Run, Single Run, Continuous Wave, Squelch Run
d) Trigger Level : TTL Level
e) Marker Modes : Marker, Delta Marker
Memory
a) Trace Storage : 100 Waves
b) Setup Storage : 100 States
Display
a) Type : Mono STN LCD
b) Resolution : 192 x 192
c) LCD Backlight : On/ Off/ Auto
d) Mode : Spectrum, Multi Bar
Input
a) RF Input Connector : N Type Female, 50 ohm
b) Maximum Input Power : Max. + 10 dBm, 5V RMS
Frequency Counter
a) Range : 9 MHz to 2.9 GHz
b) Resolution : 7 Digits
c) Sampling Time : 1 sec
d) Input Impedance : 50 ohm
e) Max. Input Voltage : Max. 5 Vrms
f) RF Input Connector : BNC type, 50 ohm
g) Data Memory : 10 data
General Specification
a) Operation Temperature : 0 to 40 deg
b) Humidity : 35RH to 85RH
c) Storage Temperature : -10 to 50 deg.
d) Size : 9.5 " H x 4.0 " W x 1.8 " D
e) Weight : 1.4 lbs
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 3006 2 Channel, 60 MHz Digital Storage Oscilloscope
Features
1. 60 MHz Bandwidth with 2 Channels
2. 500MSa Real-time Sampling Rate
3. 25GSa/ s Equivalent-Time Sampling Rate
4. Large 7-inch Color Display
5. Record Length up to FFT
6. Multi-Languages Support
7. USB Host and Device Connections
Specifications
Vertical Specifications
a) Channels : 2
b) Bandwidth : 60 MHz
c) Rise Time : 5.8ns ( Approx.)
d) Input Impedance : Resistance: 1 M + / - 2% ; Capacitance: ( 20+ / -5) pF
e) Polarity : Normal & Invert
f) Maximum Input : 400V ( DC + AC Peak)
g) Waveform Signal
h) Process : CH1 + / - CH2, CH1 x CH2, CH1/ CH2, FFT
i) Bandwidth Limit : 20MHz + / -% Typical
Horizontal Specifications
a) Sampling Rate : 500MSa/ s; Equivalent Max. Sampling Rate is 25GSa/ S for all Times
b) Range ( 1 - 2 - 5 Increments) : 50s/ div ~ 10ns/ div
c) Mode : Main Sweep, Main Sweep + Delay Expansion Sweep, X-Y
Trigger Specifications
a) Source : CH1, CH2, EXT., EXT/ 5, AC Line
b) Mode : Auto, Normal, Single
c) Trigger Sensitivity :
1. DC: CH1/ 2 ( typical) 1 Div from DC to 10MHz; 1.5div from 10MHz to full
2. EXT ( Typical) : 200mV from DC to 40MHz
3. EXT/ 5 ( Typical) : 1V from FC to 40MHz
4. AC: Attenuates signal below 10Hz
5. HF Reject: Attenuates signals below 15kHz
6. LF Reject: Attenuates signals below 150 kHz
7. Noise Reject: Reduces trigger sensitivity
d) Trigger Level Range : CH1, CH2: + / - Division from center of screen; EXT: + / - 1.2V; EXT/ 5: + / - 6V
e) Trigger Level Accuracy ( Accuracy is for signals having rise and fall time at max 20ns) :
1. CH1, CH2: + / -( 0.3div x V/ div) ( within + / -4 Division from center of screen)
2. EXT: + / - ( 6% of Setting + 40mV)
3. EXT/ 5: + / - ( 6% of setting + 200mV)
f) Edge Trigger : Rising, Falling, Rising & Falling
g) Pulse Width Trigger : Trigger ( when > , , 2 ; Delay 1- > 2
d) Cursor Measurement :
1. Voltage Difference between cursors V
2. Time Difference between Cursors T
3. Frequency difference between Cursors 1 T
Display
a) TFT LCD Type : 7.0 Inch Diagonal Crystal Display
b) Display Resolution : 800 x 480 Dots
General Specifications
a) USB : USB Host / USB Device
b) Power Source : AC 100V ~ 240V + / - 10% , 45Hz ~ 440Hz, Auto Selection
c) Physical Dimensions : 12.3 x 4.25 x 5.6 " inches ( 313 x 108 x 142mm)
d) Weight : 4.6lbs ( 2.08Kg)
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 3110 100mhz, 1gas/ s Sampling Rate Digital Storage Oscilloscope
Feature
1. 100 MHz Bandwidth with 2 Channels
2. 1GSa Real-time Sampling Rate
3. 25GSa/ s Equivalent-Time Sampling Rate
4. Large 7-inch Color Display
5. Record Length up to FFT
6. Multi-Languages Support
7. USB Host and Device Connections
Specifications
Vertical Specifications
a) Channels : 2
b) Bandwidth : 100 MHz
c) Rise Time : 3.5ns ( Approx.)
d) Input Impedance : Resistance: 1 M + / - 2% ; Capacitance : ( 20+ / -5) pF
e) Polarity : Normal & Invert
f) Maximum Input : 400V ( DC + AC Peak)
g) Waveform Signal
h) Process : CH1 + / - CH2, CH1 x CH2, CH1/ CH2, FFT
i) Bandwidth Limit : 20MHz + / -% Typical
Horizontal Specifications
a) Sampling Rate : 1GSa/ s; Equivalent Max. Sampling Rate is 25GSa/ S for all Times
b) Range ( 1 - 2 - 5 Increments) : 50s/ div ~ 5ns/ div
c) Mode : Main Sweep, Main Sweep + Delay Expansion Sweep, X-Y
Trigger Specifications
a) Source : CH1, CH2, EXT., EXT/ 5, AC Line
b) Mode : Auto, Normal, Single
c) Trigger Sensitivity :
1. DC: CH1/ 2 ( typical) 1 Div from DC to 10MHz; 1.5div from 10MHz to full
2. EXT ( Typical) : 200mV from DC to 40MHz
3. EXT/ 5 ( Typical) : 1V from FC to 40MHz
4. AC: Attenuates signal below 10Hz
5. HF Reject: Attenuates signals below 15kHz
6. LF Reject: Attenuates signals below 150 kHz
7. Noise Reject: Reduces trigger sensitivity
d) Trigger Level Range : CH1, CH2: + / - Division from center of screen; EXT: + / - 1.2V; EXT/ 5: + / - 6V
e) Trigger Level Accuracy ( Accuracy is for signals having rise and
fall time at max 20ns) : CH1, CH2: + / -( 0.3div x V/ div) ( within + /
-4 Division from center of screen) ; EXT: + / - ( 6% of Setting + 40mV) ;
EXT/ 5: + / - ( 6% of setting + 200mV)
f) Edge Trigger : Rising, Falling, Rising & Falling
g) Pulse Width Trigger : Trigger ( when > , , 2 ; Delay 1- > 2
d) Cursor Measurement :
1. Voltage Difference between cursors V
2. Time Difference between Cursors T
3. Frequency difference between Cursors 1 T
Display
a) TFT LCD Type : 7.0 Inch Diagonal Crystal Display
b) Display Resolution : 800 x 480 Dots
General Specifications
a) USB : USB Host / USB Device
b) Power Source : AC 100V ~ 240V + / - 10% , 45Hz ~ 440Hz, Auto Selection
c) Physical Dimensions : 12.3 x 4.25 x 5.6 " inches ( 313 x 108 x 142mm)
d) Weight : 4.6lbs ( 2.08Kg)
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 307 Digital Clamp Meter
Features
1. Measures AC/ DC current to 1000A
2. True RMS AC Measurements
3. Measures true power, apparent power and power factor
4. Auto/ Manual ranging
5. Frequency counter
6. 40 segment analog bar graph
7. 2-1/ 4 " Jaw opening
8. Meets IEC-1010 Category III 600V Safety Standards
Product Information
3-3/ 4 Digit AC/ DC Digital Clamp w/ Freq. & Power
Specifications
Volts DC
a) Ranges : 400mV, 4V, 40V, 400V, 600V
b) Best Resolution : 100ยต V
c) Accuracy : ± ( 0.5% Rgd + 3D)
d) Maximum Input : 1000V DC or 750V RMS
e) Input Impedance : 10MW
Volts AC
a) Ranges : 4V, 40V, 400V, 600V
b) Accuracy : ± ( 0.5% Rdg + 5D)
c) Maximum Input : 750V RMS
d) Input Impedance : 10MW
Resistance
a) Ranges : 400W , 4KW , 40KW , 400KW , 4MW , 40MW
b) Best Resolution : 0.1W
c) Accuracy : ± ( 1.5% + 5D)
d) Maximum Input : 250V DC or AC RMS
DC/ AC Current
a) Ranges : 400 and 1000 Amps
b) Best Resolution : 0.1A
c) Accuracy : ± ( 2.0% Rdg + 5D)
d) Maximum Input : 1000 Amps DC or AC RMS
Continuity Buzzer
a) Buzzer : Will sound at < 40W resistance
Frequency
a) Ranges : 100Hz, 1kHz, 10kHz, 100kHz, 1MHz
b) Best Resolution : 0.01Hz
c) Accuracy : ± ( 0.2% Rdg + 2D)
d) Maximum Input : 250V DC or AC RMS
Power Measurement True Power
a) Range : 600kW
b) Resolution : 1W
c) Accuracy : ± ( 2% Rdg + 2D)
d) Maximum Input : 600V or 1000A, DC or AC RMS
Power Measurement Apparent Power
a) Range : 600kVA
b) Resolution : 1VA
c) Accuracy : ± ( 2% Rdg + 2D)
d) Maximum Input : 600V or 1000A, DC or AC RMS
Power Measurement Power Factor
a) Range : 0.03 to 1
b) Resolution: 0.01
c) Accuracy : ± ( 2% Rdg + 2D)
d) Maximum Input : 600V or 1000A DC or AC RMS
General Specifications
a) Operating Temperature : 0 to 40° C at a relative humidity of 0 to 80% Rdg
b) Power : 9V battery
c) Size : 10.7 " H × 3.4 " W × 1.7 " D
d) Jaw Size : 2.25 "
e) Weight : 1.07 lbs.
f) Accessories : Manual, Carrying case, Test leads, IR RS-232, Cable and Software, Line splitter ( optional)
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 506 Digital Multimeter
Features
1. Dual display for frequency, AC voltage and Temperature measurements
2. 10 MHz frequency counter and decibel measurement.
3. True RMS AC voltage and current readings
4. RS-232 interface and software for downloading measurements to a
5. PC( model 506 only)
6. 10 memory locations and analog bar graph
7. Time and Stop watch mode with Alarm
8. Min., Max., Avg and Relative mode
9. Capacitance and Inductance measurement
10. Temperature measurement in Centigrade and Fahrenheit
11. Frequency generator, logic probe function and back light
12. Auto power off and " keep on " modes
Product Information
True RMS Digital Multimeter DMM
With features including a 3.75 digit 4000 count display, auto ranging
with analogue bar graph and a 10MHz frequency counter, this is
undoubtedly the finest multimeter we have ever evaluated. With proper
care this multimeter will last a lifetime, and is perfect for research
and development, service work and general scientific measurement
applications. Supplied complete with high quality silicon rubber leads
and durable protective carry case.
Specifications
Volts DC
a) Ranges ( 5) : 400mV to 1000V
b) Best Resolution : 0.1mV
c) Accuracy : ± ( 0.5% Rdg + 2D)
Volts AC
a) Ranges ( 5) : 400mV to 750V
b) Best Resolution : 0.1mV
c) Accuracy : ± ( 1.5% Rdg + 5D)
DC Current
a) Ranges : 400ยต A, 400mA, 20A
b) Best Resolution : 0.1ยต A
c) Accuracy : ± ( 1% Rdg + 2D)
AC Current
a) Ranges : 400ยต A, 400mA, 20A
b) Best Resolution : 0.1ยต A
c) Accuracy : ± ( 1.5% Rdg + 2D) , 50Hz to 100Hz
Resistance
a) Ranges ( 6) : 400W to 40MW
b) Best Resolution : 0.1W
c) Accuracy : ± ( 0.5% Rdg + 2D)
Decibel
a) Ranges ( 4) : -31.6 to + 59.71dB
b) Best Accuracy : ยต 0.5dB
Continuity
a) Buzzer : Sound at < 100W .
b) Display Will Read : Shrt when R 100W
Diode
a) Display Will Read
1. Shrt when V 1V
Frequency
a) Ranges ( 4) : 10kHz to 10MHz
b) Best Resolution : 1Hz
c) Accuracy : ± ( 0.01% Rdg x 1D)
d) Sensitivity : 1.5V RMS
Temperature
a) Range : -17 to 1200° C ( 0 to 2000° F)
b) Resolution : 1° C and 1° F
c) Accuracy : ± ( 3% Rdg + 3D)
Logic Probe
a) TLL Level Display Will Read
1. Lo when V is 2.0V
3. W when V is 0.8V to 2.0V
Capacitance
a) Range : 0 to 100° F
b) Resolution : 0.01° F
c) Accuracy : ± ( 3% Rdg + 5D)
Inductance
a) Range : 0 to 100H
b) Resolution : 0.01H
Miscellaneous
a) Signal Out : 2048Hz, 4096Hz, 8192Hz Square wave
b) Timer Range : 1 second to 10 hours
c) RS-232 Interface : 1200bps, 9 Pin Connector
General Specifications
a) Size : 8.0 " H x 3.6 " W x 1.5 " D
b) Weight : 1 lb.
c) Power : 9V battery
d) Supplied Accessories : Manual, Test leads, Holster, Temp adapter, " K " type temp probe, RS-232 cable and Software
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 6510 100MHz Oscilloscope
Features
1. Four traces may be simultaneously displayed in ALT-sweep
2. Five vertical display modes: CH1, CH2, Dual, Add, Subtract
3. Vertical mode triggering for displaying 2 unrelated signals
4. Trigger hold-off circuit for synchronizing complex waveforms
5. Sweep speeds to 2nS/ Div
6. 12kV acceleration voltage for bright displays of low duty cycle signals
7. Z axis input
8. TV Synchronization for either line or field patterns
9. 20MHz bandwidth limit switch for triggering signals in a noisy environment
Product Information
100 MHz 2Ch. Dual Time Base with Alt Mag.
Specifications
Vertical Amplifier ( CH 1 and CH 2)
a) Sensitivity : 5 mV/ Div to 5 V/ Div in 7 calibrated steps, ( X5 Mag 1mV/ Div to 1 V/ Div)
b) Accuracy : ± 3% ( ± 5% in X5 Mag)
c) Bandwidth ( -3dB) : DC to 100MHz
d) Rise Time : £ 3.5 ns, X5 Mag: 20MHz Bandwidth: £ 17 ns
e) Input Impedance : 1MW + 25 pF
f) Input Coupling : AC-Gnd-DC
g) Invert Channel : CH2
h) Display Modes : CH1, CH2, Add, Subtract, Dual ( Alt/ Chop)
i) Maximum Input Voltage : 400V ( DC or AC peak)
j) CH1 Signal Output : 20mV into 50W
Horizontal Sweep
a) Timebase A - Sweep Time : 50ns/ Div to 0.2 s/ Div in 21 calibrated steps ( 1-2-5)
b) Timebase A - X10 Mag : 5ns/ Div to 20ms/ Div
c) Timebase A - Accuracy : ± 3% ( ± 5% in X10 Mag)
d) Timebase A - Hold Off : Continuously adjustable to > 2X sweep time
e) Timebase B - Sweep Time : 50ns/ Div to 10ยต s/ Div in 8 steps ( 1-2-5)
f) Timebase B – Accuracy : ± 3%
g) Timebase B - Delay Time : Continuously variable from 0.2ยต s to 2s
h) Timebase B - Delay Modes : Continuous or triggered
i) Timebase B - Sweep Displays : A, B, A alt B, B triggered, X-Y
X-Y Mode
a) CH1-X axis, CH2-Y axis Sensitivity : Same as CH1 vertical amplifier
b) Bandwidth ( X-axis) : DC to 2MHz
c) Phase Error : £ 3° DC to 10kHz
Triggering
a) Trigger Modes : Auto, Normal, TV-V, TV-L
b) Source : Int. CH2, line ext.
c) Coupling : AC
d) Slope : Positive or negative
e) Trigger Sensitivity :
1. Int ( DC to 10MHz) : 0.5 Div
2. Int ( 10MHz to 100MHz) : 1.5 Div
3. Ext ( DC to 10MHz) : 200mV
4. Ext ( 10MHz to 100MHz) : 500mV
5. TV ( Int) : 1 Div Min
6. TV ( Ext) : 1V P-P
f) External Trigger Input : Impedance: 1MW + 20 pF
g) Maximum Input Volts : 400V DC or AC peak
Z Axis Modulation
a) Sensitivity : ± 5V P-P Intensity increases with a negative going voltage input
b) Bandwidth ( -3dB) : DC to 2MHz
c) Input Impedance : Approx. 2 KW
Calibrator Signal
a) Voltage : 0.5V ± 3% P-P 1kHz Square Wave
b) Duty Cycle : Approx. 50%
CRT
a) Type : 6 " rectangular CRT with internal graticule. ( 1 Div = 1cm)
b) Acceleration Voltage : 12 kV
General Specification
a) Power Requirements : AC Input Voltage: 100V, 120V, 220V, 240V selectable
b) Frequency : 50/ 60Hz
c) Power Consumption : 55W
d) Operating Temperature : 0 to 40° C at 35% to 85% relative humidity
e) Dimensions : 5.25 " H × 12.67 " W × 14.5 " D
f) Weight : 24 lbs.
g) Supplied Accessories : Manual, 1 AC Power cord, ( 2) X10 Probes.
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek G632 Tracking Generator
Protek G632 Tracking Generator
Tracking Generator for 7830 Analyzers
This Tracking Generator G632 which is an option to the Protek 7830
Handheld Spectrum analyzer allows even more flexibility in its
application and performance.
Product Information
The G632 is basically a sweep generator in which the sweep rate is
matched to that of the spectrum analyzer. The output circuitry of the
tracking generator contains a network that ensures a constant output
amplitude over the entire range being swept.
Typical Applications
a) Field Wireless Equipment Installation and Maintenance
b) General field use for Communications Installation and Maintenance
c) Cable installation and Maintenance
d) RFID Tag RF Strength Measurement
e) Jammer ( for hospital, theater and military) Performance Test
f) Satellite Antenna installation and Maintenance
g) Tapping, Hidden Camera Detection
Specifications
a) Range : 30MHz to 2.9GHz
b) Measurement range : -55dBm to -65dBm ( 5 dBm steps)
c) Amplitude units : dBm
d) RF input connector : N type connector
What’ s Included
a) G632
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 9205 2MHz Sweep Function Generator
Features:
a) 0.02Hz-2MHz( 7 Ranges)
b) Sine, Triangle, Square, Pulse, Ramp, Slewed Sine Waveform
c) Sync. Out( TTL Square Waveform)
d) Sweep Function
e) VCG Input
f) DC Offset
Specifications:
Output:
a) Frequency Range: 0.02Hz-2MHz( 7 Ranges)
b) Accuracy: ± 5% of Full Scale to 200KHz, ± 8% of Full Scale from 200KHz-2MHz
c) Amplitude: 10Vp-p in 50 Ohm Load
d) Attenuation: Fixed 20dB± 1dB, 20dB Continuity Variable
e) Impedance: 50 Ohm ± 5%
Sine Wave:
a) Flatness: Better than ± 3dB-2MHz at Max.Output AMP
b) Distortion: 2% ( 10Hz-100KHz)
Square Wave:
a) Rise/ Fall Time: 100ns or Less
Triangle Wave:
b) Linearity: 99% or More-100KHz
c) Symmetry Variation: 1: 1-4: 1
d) VCF Input: 0V-10V DC
Sweep Function
a) Mode: Linear
b) Width: 1: 1-100: 1
c) Time: 20ms-2s
General
a) Power 100/ 120/ 220/ 230V AC± 10% , 50/ 60Hz
b) Dimension: 8.2( W) x 10.68( D) x 3.04( H) inches
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 9205A 3MHz Sweep Function Generator
Protek 9205A 3MHz Sweep Function Generator
3MHz Sweep Function Generator
0.03Hz - 3MHz ( 7 Ranges) This generator handles Sine, Triangle,
Square, Pulse, Ramp and Slesed Sine Waveform, AM Modulation and
frequency counter function is included.
Features
a) 0.03Hz - 3MHz ( 7 Ranges)
b) Sine, Triangle, Square, Pulse, Ramp, Slesed Sine Waveform
c) Sync. Out( TTL Square Waveform)
d) Sweep Function
e) VCG Input
f) DC Offset
g) AM Modulation
h) Frequency Counter
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek 9205C Sweep Function Generator
Features
a) Sweep and DC-Off
b) Amplitude Expansion
c) VCF Input
d) Various waveform display by easy operation
Specification
Frequency : 0.02Hz ~ 2MHz 7 Ranges
Variable Range : 100 : 1 for each range
Output Waveform
a) Squrewave, Triangle wave, Sine wave, TTL sine wave, PULSE wave, ramp wave, distorted square wave
Accuracy
a) ± 5% ( 20KHz)
b) ± 8% ( 2MHz)
Stability : ± 0.1% ( after 20 min. preheating)
VCF Input
a) 0 ~ -10V DC
b) Output Frequency variable by input DC ( Max. Input Voltage : -13VDC)
SYM Variable Range : 1: 1 ~ 4: 1
DC OFFSET
a) ± 10V ( no load)
b) ± 5V ( 50 Ohm load)
Squarewave Characteristics
a) Elevation Time : 100ns or less ( in Max. Output)
Planewave Characteristics
a) Distortion : 2% ( 10Hz ~ 100KHz)
b) Output Level Variable : ± 0.3dB ( in Max. Output)
Trianglewave Characteristics
a) Linearity : 1% or less ( 100KHz or less)
Sweep Characteristics
a) Type : Linear
b) Time : 0.5Hz( 2s) ~ 50Hz( 20ms)
c) Width : 10: 1 ~ 1000: 1
Output Characteristics
a) Output Level : 2Vp-p ~ 20Vp-p ( No Load)
b) Degrator : 20± 1dB
c) Impedance : 50 Ohm ± 5%
Frequency Counter Characteristics
a) Display : 4 digit Red LED
b) Range : 10Hz ~ 2MHz
c) Accuracy : 0.01% ± 1count
d) Sensitivity : 50mVrms, 10Hz ~ 100Hz / 100Hz ~ 1KHz, 1KHz ~ 10KHz / 100KHz ~ 1MHz, 1MHz ~ 2MHz
e) Max. Input Voltage : 140Vp-p
f) Input Impedance : 1M Ohm
Operation Voltage
a) AC 110V, 117V, 220V, 240V ± 10% , 50/ 60Hz
Dimension & Weight
a) 300( W) x85( H) x220( D) mm, 2.5kg
Accessories
a) Power Cord 1EA
b) Fuse 2EA
c) BNC : BNC PROBE 1EA
d) Manual 1EA
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek DSO-2150 PC based Digital Storage Oscilloscope
Features:
a) High Performance with USB interface
b) Suitable and convenient for most usages
What' s Included:
a) 1 Instruction Manual
b) 2 Probes
DSO-2150
1. Maximum sampling rate : 150MS/ s
2. Realtime sampling : 150MS/ s
3. Bandwidth : 60MHz( -3dB)
4. Single shot bandwidth : 60MHz
5. Buffer size : 32K samples
6. Channels : 2 Channels
7. Voltage Range
a) 10mV ~ 5V/ div @ 1 probe
b) 100mV ~ 50V/ div @ 10 probe
c) 1V ~ 500V/ div @ 100 probe
d) 10V ~ 5000V/ div @ 1000 probe
8. Accuracy : ± 3%
9. Timebase Range : 4ns/ div ~ 1h/ div ( 1-2-4 sequence)
10. Offset Level : + / -4 Divisions
11. Coupling : AC, DC, GND
12. Impedance : 1M ohm
13. Input protection : 35Vpk( DC + peak AC; Without external attenuation)
14. Roll Mode : 1s/ div ~ 1h/ div
15. Range : 10 Divisions
16. Pre/ Post Production : 0% ~ 100%
17. Trigger TYPE : Edge trigger: Rising edge, Falling edge
18. Trigger mode : Auto, normal, and single
19. Autoset : Yes
20. Settability : 0.03 div increments
21. Trigger Level : + / -4 division
22. Measurements : Vp-p, Vmax, Vmin, Vmeans, Vrms, Vamp, Vhigh, Vlow,
positive overshoot, negative overshoot, cycle mean, cycle rms, period,
frequency, positive pulse width, negative pulse width, rise time ( 10% ~
90% ) fall time ( 10% ~ 90% ) , positive duty cycle, negative duty
cycle
23. Cursor : Time/ frequency difference, voltage difference
24. Math : Addition, Subtraction, multiplication, Division
25. FFT : Rectangular, Hanning, Hamming, Blackman Window
26. Interface : Universal Serial Bus ( USB)
27. Power
a) No external source required
b) Bus-powered from USB1.7W)
28. Calibration Signal Output : 2V, 1kHz, Square Wave
29. Trace Display : Point/ Line
30. Vertical Position Variable : Yes
31. Grid : On/ Off
32. File Management
a) Image save: .BMP, .JPG
b) Data Save: .dso
c) OLE ( Object Linking and Embedding) automation: Data generation for Microsoft excel
d) Setting save/ load
33. Print : Print in color/ mono
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek DSO-2250 PC based Digital Storage Oscilloscope
Features:
a) High Performance with USB interface
b) Suitable and convenient for most usages
What' s Included:
a) 1 Instruction Manual
b) 2 Probes
DSO-2250
1. Maximum sampling rate : 250MS/ s
2. Realtime sampling : 250MS/ s
3. Bandwidth : 100MHz( -3dB)
4. Single shot bandwidth : 100MHz
5. Buffer size : 10K ~ 512K samples
6. Channels : 2 Channels
7. Voltage Range
a) 10mV ~ 5V/ div @ 1 probe
b) 100mV ~ 50V/ div @ 10 probe
c) 1V ~ 500V/ div @ 100 probe
d) 10V ~ 5000V/ div @ 1000 probe
8. Accuracy : ± 3%
9. Timebase Range : 4ns/ div ~ 1h/ div ( 1-2-4 sequence)
10. Offset Level : + / -4 Divisions
11. Coupling : AC, DC, GND
12. Impedance : 1M ohm
13. Input protection : 35Vpk( DC + peak AC; Without external attenuation)
14. Roll Mode : 1s/ div ~ 1h/ div
15. Range : 10 Divisions
16. Pre/ Post Production : 0% ~ 100%
17. Trigger TYPE : Edge trigger: Rising edge, Falling edge
18. Trigger mode : Auto, normal, and single
19. Autoset : Yes
20. Settability : 0.03 div increments
21. Trigger Level : + / -4 division
22. Measurements : Vp-p, Vmax, Vmin, Vmeans, Vrms, Vamp, Vhigh, Vlow,
positive overshoot, negative overshoot, cycle mean, cycle rms, period,
frequency, positive pulse width, negative pulse width, rise time ( 10% ~
90% ) fall time ( 10% ~ 90% ) , positive duty cycle, negative duty
cycle
23. Cursor : Time/ frequency difference, voltage difference
24. Math : Addition, Subtraction, multiplication, Division
25. FFT : Rectangular, Hanning, Hamming, Blackman Window
26. Interface : Universal Serial Bus ( USB)
27. Power
a) No external source required
b) Bus-powered from USB1.7W)
28. Calibration Signal Output : 2V, 1kHz, Square Wave
29. Trace Display : Point/ Line
30. Vertical Position Variable : Yes
31. Grid : On/ Off
32. File Management
a) Image save: .BMP, .JPG
b) Data Save: .dso
c) OLE ( Object Linking and Embedding) automation: Data generation for Microsoft excel
d) Setting save/ load
33. Print : Print in color/ mono
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek G305 Sweep Function Generator
Features
1. Wide Bandwidth Frequency Range
2. Frequency Counter
3. Gate and Trigger Oscillation
4. Burst Waveform Oscillation
5. DC Offset
6. CW / LOG
7. Variable Waveform Symmetry
Specification
Frequency Characteristics
Frequency Characteristics : 0.01Hz ~ 10MHz 9 Ranges
Output Waveform
a) Sine wave, Triangle wave, Square wave, Ramp wave, Pulse wave
b) Distortion : 10Hz ~ 50MHz ; 0.5% or less
c) Square wave Rise/ Fall Time : 25ns or less
d) Symmetry Transformation : 20: 80 ~ 80: 20 ( 0.01Hz ~ 10MHz)
Frequency Measurement Range
a) 1Hz ~ 10MHz
b) Gate Time : 0.01s, 0.1s, 1s, 10s ± 1 count
c) Sensitivity : 50mVrms
d) Impedance : 1M Ohm m 35pF
e) Max. Input Voltage : 250V ( DC + AC rms)
Operation Mode : CW, BURST, SWEEP, TRIG, GATE
Output Characteristics
a) Output Level : ( Open Circuit) : 20Vp-p
b) Degradation : 0, 20, 40, 60dB
c) Impedance : 50 Ohm± 10%
d) DC Offset : Max.± 10V( Open Circuit)
e) SYNC Output : TTL Level
f) GCV Output : 0 ~ 5V
g) SWEEP Output : 0 ~ ( -5V)
h) SWEEP/ BURST GATE Output : TTL Level
Amplitude Modulation
a) Modulation Level : 0 ~ 100% Variable
b) Input Signal Level : Max. 5Vp-p
VCG
a) Frequency Range : Max. 1000 : 1
b) Input Level : 0 ~ -50 ( ± 20% )
TIME BASE
a) Frequency : 10MHz ± 3 x 10-5/ M
Operation Voltage : AC 110V, 117V, 220V, 240V ± 10% , 50/ 60Hz
Dimension & Weight : 300( W) x98( H) x300( D) mm, 4kg
Accessories
a) Power Cord 1EA
b) Fuse 2EA
c) BNC : BNC 1EA
d) Manual 1EA
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek DSO-5200A PC based Digital Storage Oscilloscope
Protek DSO-5200A PC based Digital Storage Oscilloscope
1. High Performance with USB interface
2. Suitable and convenient for most usages
General Specifications
1. Maximum sampling rate : Realtime sampling 100MS/ s
2. Equivalent Sampling : 25GS/ s
3. Bandwidth : 200MHz( -3dB)
4. Single shot bandwidth : 100 MHz
5. Buffer size : 10K ~ 512K samples
6. Channels : 2 Channels
7. Voltage Range
a) 10mV ~ 10V/ div @ 1 probe
b) 100mV ~ 100V/ div @ 10 probe
c) 1V ~ 1000V/ div @ 100 probe
d) 10V ~ 10000V/ div @ 1000 probe
8. Accuracy : ± 3%
9. Timebase Range : 2ns/ div ~ 1h/ div ( 1-2-4 sequence)
10. Offset Level : + / -4 Divisions
11. Coupling : AC, DC, GND
12. Impedance : 1M ohm
13. Input protection : 35Vpk( DC + peak AC; Without external attenuation)
14. Roll Mode : 1s/ div ~ 1h/ div
15. Range : 10 Divisions
16. Pre/ Post Production : 0% ~ 100%
17. Trigger TYPE : Edge trigger: Rising edge, Falling edge
18. Trigger mode : Auto, normal, and single
19. Autoset : Yes
20. Settability : 0.03 div increments
21. Trigger Level : + / -4 division
22. Measurements : Vp-p, Vmax, Vmin, Vmeans, Vrms, Vamp, Vhigh, Vlow,
positive overshoot, negative overshoot, cycle mean, cycle rms, period,
frequency, positive pulse width, negative pulse width, rise time ( 10% ~
90% ) fall time ( 10% ~ 90% ) , positive duty cycle, negative duty
cycle
23. Cursor : Time/ frequency difference, voltage difference
24. Math : Addition, Subtraction, multiplication, Division
25. FFT : Rectangular, Hanning, Hamming, Blackman Window
26. Interface : Universal Serial Bus ( USB)
27. Power
a) No external source required
b) Bus-powered from USB1.7W)
28. Calibration Signal Output : 2V, 1kHz, Square Wave
29. Trace Display : Point/ Line
30. Vertical Position Variable: Yes
31. Grid : On/ Off
32. File Management
a) Image save: .BMP, .JPG
b) Data Save: .dso
c) OLE ( Object Linking and Embedding) automation : Data generation for Microsoft excel
d) Setting save/ load
33. Print : Print in color/ mono
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek M733 Frequency RF Power Meter
Features
a) Lightweight, hand-held instrument
b) Frequency range: up to 2.9GHz
c) Hold/ Run modes
d) Meter zero function
e) 3 1/ 2 Digit LCD
f) CW power 0.1mW to 500mW( LiProteked duration up to 1W)
g) Full-scale ranges: 1.999mW, 19.99mW, 199.9mW, 1999mW
h) High-impact case, rugged design
i) LOW Battery detect and display
Specifications
a) Frequency Range 10’ ~ 2.9“
b) RF Input Power Ranges( Full Scale) 1.999mW, 19.99mW,
c) 199.9mW, 1999mW, 2mw
d) Accuracy ± 10% of Full Range, 10’ ~ 1“
e) ± 15% of Full Range, 1“ ~ 2.9“
f) Max Input/ Protection 500» continuous, no damage
g) 1W for 10 seconds max
h) Input Connection N-Type Female ; 50 ohm, Return Loss < -18dBRL
i) N to SMA( F) Adaptor option
j) Battery 9V Battery× 2pcs
k) Operation Temperature + 10 to + 40
l) Storage Temperature -20 to + 70
m) Dimensions( approx.) 89( W) × 160( H) × 45.7( D) mm
n) Weight 900g
Application
a) IF and RF system testing
b) RF amplifier testing
c) CATV testing and troubleshooting
d) Wireless consumer products testing
e) Base station testing and troubleshooting
f) Cellular and PCS phones
g) Two-way radio
h) Trunk radio
i) Field Service
j) Manufacturing
Specification
1. Frequency Range : 10MHz to 2.9GHz
2. RF Signal Input Power : 2mW to 500mW Max,
3. Accuracy
• + 20° C to + 30° C
• ± 10% [ mW] @ 10MHz to 1GHz
• ± 15% [ mW] @ 1GHz to 2.9GHz
• + 10° C to + 20° C, + 30° C to + 40° C
• ± 15% [ mW] @ 10MHz to 1GHz
• ± 20% [ mW] @ 1GHz to 2.9 GHz
4. Extra Functions
• Auto-Scale Function
• ' Lo BAT' Message Output Function ( Low Battery)
• ' HPI' Message Output Function ( High Power Input)
• ' LPI' Message Output Function ( Low Power Input)
5. LCD Type : Mono, FSTN LCD
6. Input Connector
• N-Type Female, 50AOhms, Return Loss < -18dBRL
• N-Type to SMA Female Adapter ( Option)
7. Battery : 6F22UT( 006PUT) DC + 9V Battery X 2pcs
8. Operating Temperature : + 10 to + 40° C
9. Operating Humidity : 35RH to 85RH ( RF: Relative Humidity)
10. Storage Temperature : -20 to + 70° C
11. Dimension ( Approximately) : 89mm( W) X 160mm( H) X 45.7mm( D)
12. Weight : 900g Max. ( 2 lbs.)
Info dan harga terbaik hubungi :
Ahmad Wahyudi
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jual Protek U2000A Frequency Counter
-FEATURES
1. Frequency, Period, Totalize, Ratio Measurements
2. Low Pass Filter
3. Variable Trigger Level
4. 8 Digit LED Display
5. 4 Step Gate Time Control
6. 1/ 10 Input Attenuator
7. Self Test
8. 3 Channel Input( 100MHz, 2GHz)
-SPECIFICATIONS
a) Frequency Range
b) Channel A : 0.1Hz-10MHz: Low Mode / 10MHz-100MHz: High Mode
c) Channel B : 10MHz-2GHz
Sensitivity
a) Channel A : 25mVrms( 0.1Hz-100MHz)
b) Channel C( CH B at 9100) / 25mVrms( 20MHz-1.6GHz) / 50mVrms( 10MHz-2.0GHz)
Input Characteristic
a) Impedance : 1M© 30pF( CH A, B) , 50© ( CH C)
b) Max.Input Voltage : 250V( DC+ AC rms, CH A) , 3Vrms( CH C)
c) Resolution : 0.1Hz/ 1Hz/ 10Hz/ 100Hz: Low Mode
d) 1Hz/ 10Hz/ 100Hz/ 1KHz: High Mode
e) 10Hz/ 100Hz/ 1KHz/ 10KHz: CH C
Time Base
a) Reference Oscillator : 10MHz, 3.90625MHz( CH B, C)
b) Short Term Stability : ± 3× 10-7/ Month
c) Temperature : ± 5× 10-6( 0 -40 )
d) Gate Time : 0.01/ 0.1/ 1/ 10s( CH A) / 0.0256/ 0.256/ 2.56/ 25.6s( CH C)
Ratio A/ B
a) Range : 10-100MHz( CH A) , 0.1Hz-10MHz( CH C)
b) Multiplier : 1/ 10/ 100/ 1000( 4 Mode)
c) Period : 5Hz-2MHz, 0.01/ 0.1/ 1/ 10s
d) Time Interval( T1A’ B) : 5Hz-2MHz, 1/ 10/ 100/ 1000( 4 Mode)
e) Totalize( CH A) : DC-10MHz
General
a) Power Requirement : 100/ 120/ 220/ 230V AC ± 10% , 50/ 60Hz
b) Dimension& Weight 253( W) * 280( D) * 95( H) mm/ Approx.2.4Kg
Info dan harga terbaik hubungi :
Ahmad wahyudi
Ahmad wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
website : www.raja-survey.com
indonetwork : http://alatukurmurah.indonetwork.co.id
blogger : djakartainstrument28.blogspot.com
djakartainstrument.blogspot.com
Jumat, 10 Januari 2014
Jual Osiloskop VOM VOS-620FG Dual Channel
VOM VOS-620FG Dual Channel Analog Oscilloscope w/ Frequency Counter ( 20MHz)
Fitur Standar :
* 20 MHz Dual Channel
* Sensitivitas tinggi 1mV/ DIV
* Input Z Axis
* Output CH1
* Perbesaran sweep 10 kali
* Sinkronisasi TV, mode X-Y
* Luminasi tinggi, graticule internal CRT Toshiba
* Enkoder elektronik Jepang, ringan, portabel dan dapat diandalkan
* Switch mode vertikal awet yang dilapisi penuh
* Fungsi triggering ALT. Dua sinyal independen observasi secara simultan
* Fungsi Triggering Level Lock
* Fungsi sinkronisasi otomatis
* Frekuensi kaunter bawaan 6 digit
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
www.raja-survey.com
http://alatukurmurah.indonetwork.co.id
Jual Analog/ Digital Osiloskop VOM VDS-620 Dual Channel
Features:
* 20MHz Dual Channel
* High sensitivity 1mV/ DIV
* Z Axis input
* CH1 output
* 10 times sweep magnification
* TV synchronization, X-Y mode
* High luminance, internal graticule Toshiba CRT
* Fmax = 20MS/ s
* Stop depth: 1K x CH2 + 1K x 2 ( reference Memories)
* Preset triggering function, pre-trigger signal observation
* Two channel, two reference waveform display. Simultaneous 4 waveform information
* Minimum sweeping speed is 10s/ DIV. The ratio measures the Ultra Low Frequency Signals
* Measure and display Single shot Non-Period signals
* Built in RS232 interface for communication with the computer
* Analog, ultra low speed and storage oscilloscope, three in one
* High performance with low price
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
www.raja-survey.com
http://alatukurmurah.indonetwork.co.id
Jual VOM VOS-650 Osiloskop Analog Dual Channel
Fitur:
* 50 MHz Dual Channel
* Sensitivitas tinggi 1mV/ DIV
* Input Z Axis
* Output CH1
* Perbesaran sweep 10 kali
* Sinkronisasi TV, mode X-Y
* Luminasi tinggi, graticule internal CRT Toshiba
* Enkoder elektronik Jepang, ringan, portabel dan dapat diandalkan
* Switch mode vertikal awet yang dilapisi penuh
* Fungsi triggering ALT. Dua sinyal independen observasi secara simultan
* Fungsi Triggering Level Lock
* Fungsi sinkronisasi otomatis
Info dan harga terbaik hubungi :
Ahmad Wahyudi
JL Pesantren no.64 Jurang Mangu Timur
Pondok Aren
Tangerang Selatan 15222
( Belakang Toko Bangunan NUGRAHA No.88 )
Tlp 021 3649 5553
Fax. 021 7303447
Hp . 0812-1807 0051 / 0878-7841 4326
Email : yudi.rajasurvey@gmail.com
www.raja-survey.com
http://alatukurmurah.indonetwork.co.id
Langganan:
Postingan (Atom)